At Color Europe, we use our own cookies and cookies from third parties for optimization, statistics, marketing and to target content. We use cookies to improve the user-friendliness of our site and therefore make it even easier for you to visit and use Color Europe. Click "Accept full web experience" to give your consent to the use of cookies. Read more.
  • Delivery
    Fast ShippingFast shipping from Denmark
  • Phone
    +45 70 60 80 43Mon-Fri 09-15:00
  • Check
    Professional ServiceYou get professional knowledge about all our products
  • Star
    4+ Star ReviewsOur customers give us 4+ reviews
+45 70 60 80 43 Mon-Fri 09-15:00
Customer Support Customer Support
0
0,00 £

REA VeriCube DPM (Dome Lighting) - without camera module

REA VeriCube DPM (Dome Lighting)  -  without camera module
 
Vælg Camera Modules Quantity
   
Vælg Calibration and adjustmen
   
Camera Modules focused +15mm focal plane
   
 
REA VeriCube DPM (Dome Lighting) - without camera module    
 
   £  
 
  • Price for this configuration5.756,47  £
    ex. VAT and environmental contribution fee
Expected delivery time: 10 work day(s)

Shop with confidence

  • Fast shipping or Economy shipping from Denmark

  • 100% Free Support

  • Secure shopping

  • Minimum order is 170 £

  • B2B customer needs a valid EORI number for import from European union

Description of REA VeriCube DPM (Dome Lighting) - without camera module

  • REA VeriCube DPM (Dome Lighting)
    REA VeriCube DPM and REA VeriCube DF are advanced verification units for 1D barcodes and 2D matrix codes. They can assess code quality on reflective, mirror or glossy surfaces with precision.

    REA VeriCube DF uses diffuse lighting for uniform illumination of the product surface, ensuring reliable verification of reflective and shiny surfaces regardless of their 3D geometry. Formerly problematic shadows and extraneous light are no longer an obstacle, resulting in reproducible and reliable measurement results.

    REA VeriCube DPM achieves even more diffuse lighting. By integrating DOME lighting, it can accurately and consistently verify directly marked codes on high gloss and extremely reflective surfaces. The measurement chamber incorporates a matte white tube to facilitate this, making 3D geometries, shadow formations and extraneous light irrelevant to the quality evaluation and measurement results.

    Both REA VeriCube DF and REA VeriCube DPM assess coding quality through the DPM test method ISO/IEC TR 29158. They immediately identify low first-time read speeds, enabling optimization of code print quality.

    Specifications


    - Measurement accuracy in accordance with ISO/IEC 15426-2 and ISO/IEC 15426-1
    - Red LED light 660 nm or white LED light, 4,000 °K
    - Replaceable camera module, resolution 2592 x 1944 pixels
    - The camera's focus and aperture are preset by the factory
    - Turn the key panel to adjust to the preferred measurement position
    - RJ45 Ethernet port for TCP/IP communication and PoE power supply
    - Keyboard with power, scan and customizable function keys
    - Size: 200 x 150 x 150 mm (w/l/h), with keyboard 210 mm wide
    - Weight: 2,600 g
    - Windows 10 or later, 64bit support. The Audit Trail option requires a 64-bit Windows version
    - ISO/IEC 15423: Please note that this performance standard is only valid for barcode and matrix code scanners. This does not apply to optical measuring instruments such as the REA Verifier product range. For verifiers, ISO/IEC 15426-x are the applicable performance standards.
    - ISO/IEC 15419: Please note that this performance standard is valid for barcode and matrix code labeling and code generation software, as well as for printers that print QR codes, data matrix codes and barcodes.
  • Features


    - DOME lighting
    - Contactless measurements with a CMOS camera
    - Matt white tube insert in the measuring room for extremely diffuse lighting
    - Easily replaceable camera modules to adapt to different code sizes and measuring distances
    - Different focus positions (0, +15mm, +45mm) above the glass pane to measure parts where the code cannot be placed on the pane with distance 0
    - Selectable diffuse lighting (red or white light)
    - Designed to operate in 3 positions to meet different measurement requirements: sideways, upright and upside down
    - Verification according to ISO/IEC 15415 for printed matrix codes
    - Verification according to ISO/IEC TR 29158 (formerly AIM DPM guideline 2006) for matrix codes for direct part marking
    - Verification in accordance with GS1 specifications
    - Verification of GS1 data structures, ISO/IEC 15459-x series of standards and ISO/IEC 15418 / ANSI MH10.8.2 data structure analysis
    - Verification of optional parameters to optimize the printing process
    - Multilingual user interface and reports
    - For ease of use, settings can be saved in custom profiles for quick selection
    - Specific code selection to meet the requirements of the pharmaceutical industry
    - Power supply via network cable (Power over Ethernet)
    - Easy removable and replaceable glass cover plate
    - Network compatible PC evaluation software TransWin32 for Windows (multi-user compatible)
    - Option Audit Trail for 21 CFR part 11 and CGMP requirements is available as an option